Effects of expanded polystyrene (EPS) particles on fire resistance, thermal conductivity and compressive strength of foamed concrete

Autor
Vilches-Tapia, Juan
Sayadi, Ali A.
Neitzert, Thomas R.
Clifton, G. Charles
Fecha
2016Resumen
This paper deals with the contribution of expanded polystyrene (EPS) particles on fire resistance, thermal conductivity and compressive strength of foamed concrete. The foamed (FC) and polystyrene foamed (PFC) concrete were designed for densities ranging from 1200 kg/m3 to 150 kg/m3 with an EPS volume range of 0–82.22% and water-cement ratio of 0.33. The foamed concrete (FC) with a density of 800 kg/ m3 and an EPS volume of 0% was designed as reference for polystyrene foamed concrete. The results indicated that increasing the volume of EPS causes a significant reduction of thermal conductivity, fire endurance and compressive strength of concrete.
Fuente
Construction and Building Materials, 112, 716-724Link de Acceso