Mostrar el registro sencillo de la publicación

dc.contributor.authorMoreno-Pino, Fernando
dc.contributor.authorPorras-Segovia, Alejandro
dc.contributor.authorLópez-Esteban, Pilar
dc.contributor.authorArtés-Rodríguez, Antonio
dc.contributor.authorBaca-Garcia, Enrique
dc.date.accessioned2020-10-16T18:21:23Z
dc.date.available2020-10-16T18:21:23Z
dc.date.issued2019
dc.identifier.urihttp://repositorio.ucm.cl/handle/ucm/3102
dc.description.abstractSTUDY OBJECTIVES: Consumer wearable devices may be a helpful method of assessing sleep, but validation is required for their use in clinical practice. Our aim was to validate two models of Fitbit sleep trackers that rely on both accelerometer and heart rate sensors against polysomnography in participants with obstructive sleep apnea (OSA). METHODS: Participants were adults presenting with symptoms of OSA and attending our outpatient sleep clinic. A polysomnography (PSG) was applied to all participants at the same time they were wearing a Fitbit sleep tracker. Using paired t tests and Bland-Altman plots, we compared the sleep measures provided by the wearable devices with those obtained by PSG. Since Fitbit devices’ automatic detection of sleep start time can cause bias, we performed a correction using Huber loss function-based linear regression and a leave-one-out strategy. RESULTS: Our sample consisted of 65 patients. Diagnosis of OSA was confirmed on 55 (84.6%). There were statistically significant differences between PSG and Fitbit measures for all sleep outcomes but rapid eye movement sleep. Fitbit devices overestimated total sleep time, and underestimated wake after sleep onset and sleep onset latency. After correction of bias, Fitbit-delivered measures of sleep onset latency did not significantly differ of those provided by PSG. CONCLUSIONS: Fitbit wearable devices showed an acceptable sensitivity but poor specificity. Consumer sleep trackers still have insufficient accuracy for clinical settings, especially in clinical populations. Solving technical issues and optimizing clinically-oriented features could make them apt for their use in clinical practice in a nondistant future.es_CL
dc.language.isoenes_CL
dc.rightsAtribución-NoComercial-SinDerivadas 3.0 Chile*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/cl/*
dc.sourceJournal of Clinical Sleep Medicine, 15(11), 1645-1653es_CL
dc.titleValidation of fitbit charge 2 and fitbit alta HR against polysomnography for assessing sleep in adults with obstructive sleep apneaes_CL
dc.typeArticlees_CL
dc.ucm.indexacionScopuses_CL
dc.ucm.indexacionIsies_CL
dc.ucm.urijcsm.aasm.org/doi/full/10.5664/jcsm.8032es_CL
dc.ucm.doidoi.org/10.5664/jcsm.8032es_CL


Ficheros en la publicación

FicherosTamañoFormatoVer

No hay ficheros asociados a esta publicación.

Esta publicación aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo de la publicación